Water tank self-cleaning sterilizer is a device used for disinfecting and sterilizing stainless steel water tanks. This device consists of two parts. The main unit is usually made of carbon steel and is equipped with a time controller, indicator lights, switches, and other control systems; The auxiliary machine is made of 304 stainless steel and is a stainless steel tank. Hang the water tank inside to kill bacteria and algae. Its working principle is that oxygen in the air is converted into ozone through a high-frequency and high-voltage electric field, and mixed with water in a timely manner to produce high concentration ozone water. By utilizing the strong oxidizing effect of ozone, it diffuses and kills bacteria in the water tank. So, the timer adjustment steps for the self-cleaning and disinfecting device of the water tank:
1. Press key 1 (cancel/restore) continuously for 4 times, the "" symbol on the LCD screen disappears, the timer unlocks, and this lock automatically locks 1 minute after the timer adjustment operation is completed.
2. Press key 6 (timer), and "1ON" will appear on the LCD screen.
3. Press key 4 (school week) to adjust the LCD display from last week to Monday to Sunday.
4. Press key 2 (time calibration) to adjust the clock time required to turn on the light box.
5. Press key 3 (calibration) to set the desired minute time for the light box to turn on.
6. Press key 6 (timer), and "1OFF" will appear on the LCD screen.
7. Press key 2 (time calibration) to adjust the clock time required to turn off the light box.
8. Press key 3 (calibration) to set the desired minute time for the light box to turn off.
9. After setting, press the 6th key continuously (timer), check that the time display for 2ON and all subsequent times should be empty, and only the first group of "1ON, 1OFF" should have time display. The timer on/off time setting is complete.
10. Press the 7th key (clock) to return to the timer electronic watch state, confirm that the time is accurate. If it is not accurate, press and hold the 7th key, then press the 2nd key (time calibration) to adjust the hour, and press the 3rd key to adjust the minute.
11. Press key 5 (automatic/manual) to adjust the "" on the LCD screen to point to automatic. The order of adjustment during non light box opening time is as follows: first adjust "" to the "on" position, confirm that the light box is turned on, then adjust "" to the automatic position. At this time, the light box should remain lit, then adjust "" to the "off" position, confirm that the light box is closed, and finally adjust "" to the automatic position. At this time, the light box should remain unlit; The order of adjustment during the opening time of the light box is: first adjust "" to the "on" position, confirm that the light box is turned on, and then adjust "" to the automatic position. At this time, the light box should remain on.
12. All operations are completed.